<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>44974</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: newline error, check drum encoder and LC-BP cable
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The focus servo requires the NEWLINE signal from the MPE. This signal
is in the DB9 connector between the MPE backplane and the head. If this
signal is not detected during a plot, this error will be generated.
</text></DescriptionText>
<DescriptionText><text>
Note that this error is also generated if focus_mode is not 1 or 2 and "focus
on" is specified without imaging. Without the drum spinning and PLL on and locked
only focus modes 1 and 2 can be used.
</text></DescriptionText>
<DescriptionText><text>
It is possible for this error to be reported because of a system pressure problem.  If the system pressure
drops below the threshold for a short period of time, the drum will be stopped but the error may not be
reported properly.  As of drum module V1.32 (check the "list modules" command, if that command doesn't exist,
your firmware is too old), then the statement "WARNING: Low air pressure detected!" will be displayed a few
seconds prior to the error being reported.  If that message was displayed, then the system pressure should be
checked.  Make sure the supply has enough volume, and also check for other devices using the same air line.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Newline signal not received by head.
</Cause>
<Cause>
System pressure problems.
</Cause>
<LastModified>
03-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../prm/ehi_hdm_fmode.xml</LinkAddress><LinkTitle>PRM: hdm fmode</LinkTitle></Link>
<Link><LinkAddress>../commands/focus_-focus_mode-.xml</LinkAddress><LinkTitle>Command: focus &lt;focus mode&gt;</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:42 2008 PST
</Updated>
<Links>
</Links>
</Error>